How To Disassemble Braun Clean And Clear
Braun's Clean & Charge (cc) systems are probably the almost popular self-cleaning stations out at that place.
I reason for this is of course the prevalence of Braun electric shavers, but the stations themselves are useful and practical besides.
And with 3rd-political party cleaning solutions being cheap and effective, I think Braun'south stations are well worth information technology, particularly with the Series 5, vii or 9 that don't toll a whole lot more than than the solo models.
Incidentally, Braun stations are also the most probable to get clogged over time.
The manufacturer even mentions this explicitly in the troubleshooting section of the user transmission, only the directions are extremely vague and not particularly helpful.
So, in this guide, I will go over how to identify a clogged Braun cleaning station and how to unclog information technology in a few easy steps (with detailed images).
Allow'southward get started!
Table of Contents
- Signs of a clogged Braun cleaning base
- How to unclog a Braun Clean & Charge station
- 1. Unplug the power cord from the station and remove the cartridge.
- 2. Locate the small drain pigsty.
- three. Using a wooden toothpick or something similar, clear the drain hole.
- 4. [Optional] Remove the outer housing of the station.
- Dealing with a stuck impeller
- The station (still) splashes fluid and likewise leaks during cleaning
- How to avoid getting a Braun station clogged
Signs of a clogged Braun cleaning base
A clogged bleed is the nearly mutual trouble with Braun cleaning stations.
While they may seem complicated at start, the stations are really pretty basic in the manner they are synthetic and in the style they work.
Basically, the cleaning fluid is pumped from the cartridge through a tube, it passes through the shaving head, then flows back into the cartridge through a modest bleed hole.
Using my mad Photoshop skills, I tried to illustrate this in the graphic beneath:
The bottom of the cleaning chamber is actually slanted towards the drain hole then that the fluid would naturally flow dorsum into the cartridge by gravity lonely.
That tiny drain pigsty (reddish arrow) is the culprit for bottleneck the station.
Pare oils, hairs, dead skin and all sorts of gunk can form a plug that completely blocks the minor drainage, so the cleaning fluid doesn't take anywhere to go.
If you experience some of the following situations, you're most likely dealing with a clogged drainage.
- The cleaning fluid stays up and doesn't bleed back into the cartridge (or it takes a long time to do and then);
- The shaving head is dripping wet fifty-fifty hours after the cleaning cycle ended;
- The shaving head is dirty, particularly on the within of the cassette;
- In that location's an increased consumption of cleaning fluid.
Luckily, cleaning a clogged Braun station is very piece of cake and y'all don't demand any technical skills or special tools.
Here'southward how to do it, step by pace.
How to unclog a Braun Clean & Charge station
i. Unplug the ability cord from the station and remove the cartridge.
If there'due south any liquid accumulated in the cleaning chamber of the station, make sure to remove the liquid earlier proceeding to the next footstep.
ii. Locate the small-scale bleed pigsty.
Regardless of your Braun station model, there are two holes on the within of the station: one towards the meridian of the sloped inner chamber and one on the bottom corner.
Here's the drain on a Braun Series 9 station:
And once more on a Series 7:
Since the cartridge has a fine mesh filter that retains all the dirt, information technology's very unlikely that the other hole (at the elevation) will e'er get clogged.
The fluid enters the sleeping accommodation via the hole at the top, it's flushed through the shaving head, then goes back into the cartridge through the drain pigsty at the bottom — that's the one we're trying to unclog.
iii. Using a wooden toothpick or something similar, articulate the drain hole.
With the station open up, merely push any debris and gunk with the toothpick until it falls from the drainage.
You lot should also inspect the inner sleeping accommodation and clean it of any hardened dirt, making sure not to push any of it into the drain. Optionally, you tin can apply a damp cloth as well.
When held at the right angle, you should be able to meet daylight shining through a clean drain pigsty.
If needed, you tin plow the station upside down and clean any remaining dirt from the opposite side of the drain tube — this may exist a chip difficult to perform without removing the top office of the station (see step four below).
Important: Make certain however you lot're not using water as the station itself is Not waterproof and cannot exist cleaned with h2o. That can impairment the electronic components irreversibly.
That's pretty much it.
four. [Optional] Remove the outer housing of the station.
If the clogging is severe, you may need to partially detach the station in order to get better access to the bleed tube from below.
Commonly, this won't exist necessary, but if there's still some gunk that you cannot remove, hither'due south how to do it.
Holding the station upside downward, locate the four tabs that lock the housing in place.
Here are two of them, in that location are two more simply like these:
With your fingernail, gently push each tab inward. You should hear a click when a tab is unlocked.
Once the four tabs are unlocked, press the button that opens the station while likewise pushing down on the oval part of the charging port and so that they'll articulate the housing and the inner role of the station will slide out.
Once the outer crush is removed, locate the tube corresponding to the drain pigsty you just cleaned at footstep 3 and using the same toothpick or a q tip remove whatever remaining dirt from the vent.
Assemble the station back in the same order, making certain to lock the four tabs by pressing them outward until they snap into place with a click.
The procedure is exactly the same for a Series 5, seven, 8 or nine station. Unfortunately I don't have a Series three station right now, just it shouldn't be much different.
Dealing with a stuck impeller
A less common trouble with Braun cleaning stations is related to the impeller.
The pump has this small propeller that rotates and pumps the fluid from the cartridge into the cleaning sleeping room of the station.
In fourth dimension, it can get clogged with oils, hairs, and dirt and it can really get stuck.
When this happens, you'll nevertheless hear the station working, but at that place'll exist no cleaning fluid being pumped and the shaving head volition remain dry afterward the cleaning wheel.
Luckily, the impeller is very like shooting fish in a barrel to unstuck.
Hither's how to do it.
1. First, disconnect the station from the cord and remove the cleaning cartridge.
With the station opened, turn information technology upside down to go access to the pump. You shouldn't need to remove the outer housing of the station for this.
2. Locate the impeller and turn information technology gently using a toothpick or any like object.
Equally mentioned previously, the impeller is a small propeller that needs to plow freely in order for the pump to work.
Regardless of your Braun station, you should be able to easily locate it.
With a toothpick or a small screwdriver, gently give it a few turns and loosen any dirt buildups that got stuck in there.
Don't effort to remove all the clay inside every bit it will get flushed anyway in one case the pump starts working normally.
Of import: make sure not to misfile the impeller with the outer comprehend (that besides kind of looks similar ane).
The station (still) splashes fluid and also leaks during cleaning
While not technically a bottleneck issue, it is somewhat related to the topic and it seems to happen more frequently than I thought.
Precisely, if your Braun cleaning station sprays fluid on your countertop and also leaks from the bottom and you're positive that the bleed pigsty isn't chock-full, here'south how to solve the problem.
There'south a safe gasket surrounding the impeller housing that normally seals the space betwixt it and the big opening of the cartridge.

In time, that gasket will deform and won't seal up properly against the cartridge, allowing the fluid to escape.
This seems to happen more often with Braun Series ix and Series 5 stations.
In gild to ready it, you lot must first remove the outer housing of the station (just follow the instructions at step 4 above).
Locate the impeller housing and visually inspect the rubber gasket sitting at the base.
It should be flared uniformly around the housing (2 to 3mm).
If you notice areas where information technology is likewise close or touching the housing, run your finger between the gasket and housing and push it outward and then information technology stays clear of the plastic cylinder.
That'south pretty much it. Put the station back together and don't forget to secure the clips as well.
Props to John for sharing the prepare.
How to avert getting a Braun station chock-full
Depending on a few factors, you lot may never have to deal with a blocked bleed hole on your Braun station.
But fifty-fifty if that happens and yous'll accept to have matters into your own easily, the procedure is very easy and straightforward every bit nosotros just saw.
Hither are a few tips to reduce the likelihood of the station getting clogged in the future.
✓ Remove most of the hairs from the cassette before cleaning the shaver in the station.
Simply remove the cassette and gently tap the plastic frame on the edge of your sink to remove the hairs.
You tin so blow over it or use the minor brush (just simply on the inside of the cassette, not directly over the foils) to clear whatever remaining pilus strands.
A can of compressed air also works cracking.
This simply takes a few seconds, simply it does brand a difference and will also allow you to get more cleaning cycles out of a cartridge.
✓ If you employ shaving cream, rinse the head with h2o and remove any foam residue before cleaning the shaver in the station.
Hardened lather can lead to a clogged drain probably more than anything and it tin also cause force per unit area buildup inside the cartridge.
The shaver must be dry before cleaning information technology in the station, so shake off the water and gently pat it dry out with a towel. Y'all may need to remove the cassette and allow the parts air dry as well.
✓ Clean the inner sleeping room of the station with a damp material from time to fourth dimension.
Fine hairs and gunk will accumulate inside the cleaning sleeping accommodation and some of it can end up blocking the drain pigsty.
✓ Change the cleaning fluid when it becomes excessively contaminated with clay.
Even if at that place'south a filter inside the cartridge, some sludge may still laissez passer through information technology. This is bad for the hygiene of your shaver and it can also block the drain tube in time.
And since third-party cleaning solutions are really inexpensive, information technology'due south not worth pushing it beyond a certain signal.
That pretty much concludes this guide. A clogged drain is by far the nigh common trouble with Braun stations, but luckily one that can be easily fixed.
If you have any further questions or simply want to share your experience, make certain to leave a comment below.
Disclaimer: shavercheck.com and the author of this post are non responsible for whatsoever harm caused to your device. Always follow the manufacturer'south instructions.
Source: https://shavercheck.com/unclog-braun-cleaning-station/
Posted by: smithcoulp1969.blogspot.com